Studies of the response of the prototype CMS hadron calorimeter, including magnetic field effects, to pion, electron, and muon beams

Budd, Howard; de Barbaro, Pawel; etc..

Nuclear Instruments and Methods in Physics Research Section A 457, 75-100 (2001)

We report on the response of a prototype CMS hadron calorimeter module to charged particle beams of pions, muons, and electrons with momenta up to 375 GeV/c. The data were taken at the H2 and H4 beamlines at CERN in 1995 and 1996. The prototype sampling calorimeter used copper absorber plates and scintillator tiles with wavelength shifting fibers for readout. The effects of a magnetic field of up to 3 T on the response of the calorimeter to muons, electrons, and pions are presented, and the effects of an upstream lead tungstate crystal electromagnetic calorimeter on the linearity and energy resolution of the combined calorimetric system to hadrons are evaluated. The results are compared with Monte Carlo simulations and are used to optimize the choice of total absorber depth, sampling frequency, and longitudinal readout segmentation.

download this article



Home | People | Education | Research | Events | Resources | Links | Internal ]

University of Rochester
Department of Physics & Astronomy
Bausch & Lomb Hall
P.O. Box 270171
500 Wilson Boulevard
Rochester, NY 14627-0171
phone:
fax:
(585) 275-4351
(585) 273-3237
HOME INDEX SEARCH
This page was last updated Mon, Nov 23, 2009; 10:30:03 AM
Comments? Contact webmaster@pas.rochester.edu

This page is located at:
http://spider.pas.rochester.edu:8080/wwwPAS/PASforms/events/pubsShowItem$abstract=We+report+on+the+response+of+a+prototype+CMS+hadron+calorimeter+module+to+charged+particle+beams+of+pions,+muons,+and+electrons+with+momenta+up+to+375+GeV%2Fc.+The+data+were+taken+at+the+H2+and+H4+beamlines+at+CERN+in+1995+and+1996.+The+prototype+sampling+calorimeter+used+copper+absorber+plates+and+scintillator+tiles+with+wavelength+shifting+fibers+for+readout.+The+effects+of+a+magnetic+field+of+up+to+3+T+on+the+response+of+the+calorimeter+to+muons,+electrons,+and+pions+are+presented,+and+the+effects+of+an+upstream+lead+tungstate+crystal+electromagnetic+calorimeter+on+the+linearity+and+energy+resolution+of+the+combined+calorimetric+system+to+hadrons+are+evaluated.+The+results+are+compared+with+Monte+Carlo+simulations+and+are+used+to+optimize+the+choice+of+total+absorber+depth,+sampling+frequency,+and+longitudinal+readout+segmentation.&authors=Budd,+Howard;+de+Barbaro,+Pawel;+etc..&journal=Nuclear+Instruments+and+Methods+in+Physics+Research+Section+A&page=75-100&title=Studies+of+the+response+of+the+prototype+CMS+hadron+calorimeter,+including+magnetic+field+effects,+to+pion,+electron,+and+muon+beams&url=http%3A%2F%2Fwww.sciencedirect.com%2Fscience%3F_ob%3DMImg%26_imagekey%3DB6TJM-423YM1F-7-84%26_cdi%3D5314%26_user%3D483663%26_orig%3Dsearch%26_coverDate%3D01%252F11%252F2001%26_sk%3D995429998%26view%3Dc%26wchp%3DdGLbVzz-zSkzk%26md5%3Df8b6cb9e6f485dd73d56dd5c11a9000e%26ie%3D%2Fsdarticle.pdf&vol=457&year=2001